Criteria for awarding the EU Ecolabel to water-based heaters are set for each of the following aspects:
Minimum energy efficiency
Minimum seasonal space heating energy efficiency
Minimum water heating energy efficiency
Greenhouse gas emission limits
Refrigerant and secondary refrigerant
Nitrogen oxide (NOx) emission limits
Carbon monoxide (CO) emission limits
Organic gaseous carbon (OGC) emission limits
Particulate matter (PM) emission limits
Noise emission limits
Hazardous substances and mixtures
Substances listed in accordance with Article 59(1) of Regulation (EC) No 1907/2006 of the European Parliament and of the Council [Regulation (EC) No 1907/2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), establishing a European Chemicals Agency, amending Directive 1999/45/EC and repealing Council Regulation (EEC) No 793/93 and Commission Regulation (EC) No 1488/94 as well as Council Directive 76/769/EEC and Commission Directives 91/155/EEC, 93/67/EEC, 93/105/EC and 2000/21/EC (OJ L 396, 30.12.2006, p. 1).]
Plastic parts
Product design for sustainability
Installation instructions and user information
Information appearing on the EU Ecolabel
Table 1 presents the applicability of the different criteria to each heat generator technology. In the case of a package of space heater, it shall comply with all the criteria applicable to each of the heat generator technologies it is made of. Those criteria, for which there is a specific methodology aimed at the packages of space heaters, shall be applicable to the package of space heaters as a whole.
The specific assessment and verification requirements are indicated within each criterion.
Where the applicant is required to provide declarations, documentation, analyses test reports, or other evidence to show compliance with the criteria, these may originate from the applicant or his supplier or both.
Where possible, the testing shall be performed by laboratories that meet the general requirements of European Standard EN ISO 17025 or equivalent.
Test methods for each criterion, unless specified otherwise, shall be those described in the relevant Standards as indicated in Table 2 and Table 3 (where applicable). Where appropriate, test methods other than those indicated for each criterion may be used if the competent body assessing the application accepts their equivalence. The methodology to calculate the seasonal space heating emissions is indicated in Table 4.
Where appropriate, competent bodies may require supporting documentation and may carry out independent verifications.
Heat generator technology
Criteria
Gas boiler heaters | Liquid fuel boiler heaters | Solid fuel boiler heaters | Electric boiler heaters | Fuel-driven heat pump heaters | Electrically-driven heat pump heaters | Cogeneration space heaters
1(a) — Minimum seasonal space heating energy efficiency
x | x | x | x | x | x | x
1(b) — Minimum water heating energy efficiency (applicable to combination heaters only)
x | x | | x | x | x | x
2 — Greenhouse gas emission limits
x | x | x | x | x | x | x
3 — Refrigerant and secondary refrigerant
x | x |
4 — Nitrogen oxide (NOx) emission limits
x | x | x | | x | | x
5 — Carbon monoxide (CO) emission limits
x | x | x | | x | | x
6 — Organic carbon (OGC) emission limits
x | | | |
7 — Particulate matter (PM) emission limits
x | x | | | | x
8 — Noise emission limits
x | x | x
9 — Hazardous substances and materials
x | x | x | x | x | x | x
10 — Substances listed in accordance with Article 59(1) of Regulation (EC) No 1907/2006
x | x | x | x | x | x | x
11 — Plastic parts
x | x | x | x | x | x | x
12 — Product design for sustainability
x | x | x | x | x | x | x
13 — Installation instructions and user information
x | x | x | x | x | x | x
14 — Information appearing on the EU Ecolabel
x | x | x | x | x | x | x
[An updated version of the standard is expected to cover cogeneration space heaters as well (see Draft prEN 50465:2011 Gas appliances — Combined Heat and Power appliance of nominal heat input inferior or equal to 70 kW).]
Number | Title
Gas boiler heaters
EN 676 | Automatic Forced draught burners for gaseous fuels
EN 15502-1 | Gas-fired heating boilers — Part 1: General requirements and tests
Liquid fuel boiler heaters
EN 267 | Automatic forced draught burners for liquid fuels
EN 303-1 | Heating boilers — Part 1: Heating boilers with forced draught burners — Terminology, general requirements, testing and marking
EN 303-2 | Heating boilers — Part 2: Heating boilers with forced draught burners — Special requirements for boilers with atomizing oil burners
EN 303-4 | Heating boilers — Part 4: Heating boilers with forced draught burners — Special requirements for boilers with forced draught oil burners with outputs up to 70 kW and a maximum operating pressure of 3 bar — Terminology, special requirements, testing and marking
EN 304 | Heating boilers — Test code for heating boilers for atomizing oil burners
Solid fuel boiler heaters
EN 303-5 | Heating boilers — Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW — Terminology, requirements, testing and marking
EN 14918 | Solid biofuels — Determination of calorific value
Electric boiler heaters
EN 60335-2-35 | Household and similar electrical appliances — Safety — Part 2-35: Particular requirements for instantaneous water heaters
Fuel-driven heat pump heaters
EN 12309 series | Gas-fired absorption and adsorption air-conditioning and/or heat pump appliances with a net heat input not exceeding 70 kW
DIN 4702, Part 8 | Central heating boiler; determination of the standard efficiency and the standard emissivity
Electrically-driven heat pump heaters
EN 14511 series | Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling
EN 14825 | Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling — Testing and rating at part load conditions and calculation of seasonal performance
Cogeneration space heaters
EN 50465 | Gas appliances — Fuel cell gas heating appliances — Fuel cell gas heating appliance of nominal heat input inferior or equal to 70 kW
ISO 3046-1 | Reciprocating internal combustion engines — Performance — Part 1: Declarations of power, fuel and lubricating oil consumptions, and test methods — Additional requirements for engines for general use
Number | Title
Nitrogen oxide emissions
EN 14792 | Stationary source emissions — Determination of mass concentration of nitrogen oxides (NOx) — Reference method: Chemiluminescence
Carbon monoxide emissions
EN 15058 | Stationary source emissions — Determination of the mass concentration of carbon monoxide (CO) — Reference method: Non-dispersive infrared spectrometry
Organic gaseous carbon emissions
EN 12619 | Stationary source emissions — Determination of the mass concentration of total gaseous organic carbon at low concentrations in flue gases — Continuous flame ionisation detector method
Particulate matter emissions
EN 13284-1 | Stationary source emissions — Determination of low range mass concentration of dust — Part 1: Manual gravimetric method
Noise emissions
EN ISO 3744 | Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Engineering methods for an essentially free field over a reflecting plane (ISO 3744:2010)
EN ISO 3746 | Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Survey method using an enveloping measurement surface over a reflecting plane (ISO 3746:2010)
EN 12102 | Air conditioners, liquid chilling packages, heat pumps and dehumidifiers with electrically driven compressors for space heating and cooling — Measurement of airborne noise — Determination of the sound power level
Where:
Es are the seasonal space heating emissions.
Es,p are the emissions of respectively particulate matter, organic gaseous compounds, carbon monoxide and nitrogen oxides measured at 30 % or 50 % of rated heat output, as applicable.
Es,r are the emissions of respectively particulate matter, organic gaseous compounds, carbon monoxide and nitrogen oxides measured at rated heat output.
Type of solid fuel boiler | Formula
Manually stoked solid fuel boilers that can be operated at 50 % of the rated heat output in continuous mode, and automatically stoked solid fuel boilers | Es0,85Es,p0,15Es,r
Manually stoked solid fuel boilers that cannot be operated at 50 % or less of the rated heat output in continuous mode, and solid fuel cogeneration space heaters | EsEs,r
The seasonal space heating energy efficiency ηs of the water-based heater shall not fall below the limit values set out in Table 5.
Heat generator technology | Minimum seasonal space heating energy efficiency
All heaters except solid biomass boiler heaters | ηs ≥ 98 %
Solid biomass boiler heaters | ηs ≥ 79 %
The seasonal space heating energy efficiency shall be calculated in accordance with the procedures set out in Annex III to Regulation (EU) No 813/2013 and in Annex VII to Commission Delegated Regulation (EU) No 811/2013 [Commission Delegated Regulation (EU) No 811/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of space heaters, combination heaters, packages of space heater, temperature control and solar device and packages of combination heater, temperature control and solar device (OJ L 239, 6.9.2013, p. 1).], including, where applicable, the harmonised standards the reference numbers of which have been published for this purpose in the Official Journal of the European Union, or other reliable, accurate and reproducible methods that take into account the generally recognised state-of-the-art methods and that meet the conditions and technical parameters set out in Annex III of Regulation (EU) No 813/2013.
For solid fuel boiler heaters, ηs shall be calculated in accordance with the procedures referred to in point (i), taking into account the following additional requirements:
the calculation of ηs shall be based on the gross calorific value of the wet fuel (as received) GCVar, which corrects for the moisture content in the fuel but includes in the energy content the latent heat energy stored in hydrogen that is oxidised to water in the combustion process. The principles laid down in Standard EN 303-5 shall apply to estimate ηs, while GCVar instead of the net calorific value of the wet fuel (as received) NCVar shall be used for the calculation of ηs.
for determining the calorific value of solid biomass, the principles laid down in Standard EN 14918 shall apply.
The gross calorific value of the wet fuel at constant volume GCVar,V can be derived as follows:
GCVar,V = GCVdry,V × (100 – m)/100 [MJ/kg]
where:
m is the moisture content of the wet fuel (percentage by mass)
GCVdry,V is the gross calorific value of the dry fuel (moisture-free) at constant volume
The gross calorific value of the dry fuel at constant volume GCVdry,V can be derived as follows:
GCVdry,V = NCVdry,P + 0,2122 × Hdry + 0,0008 × (Odry + Ndry) [MJ/kg]
where:
NCVdry,P is the net calorific value of the dry fuel (including ash) at constant pressure
Hdry is the hydrogen content of the dry fuel (percentage by mass)
Odry is the oxygen content of the dry fuel (percentage by mass)
Ndry is the nitrogen content of the dry fuel (percentage by mass)
The net calorific value of the dry fuel at constant pressure NCVdry,P can be derived as follows:
NCVdry,P = NCVar,P × 100/(100 — m) + 2,443 × m/(100 — m) [MJ/kg]
where:
NCVar,P is the net calorific value of the wet fuel at constant pressure
It shall be noted that with combining (c), (d) and (e), GCVar,V can be derived from NCVar,P as follows:
GCVar,V = NCVar,P + [0,2122 × Hdry + 0,0008 × (Odry + Ndry)] × (100 — m)/100 + 0,02443 × m [MJ/kg]
The applicant shall declare that the product complies with this criterion and provide test results conducted in accordance with the testing procedure indicated in the EN standards (including transitional methods where applicable) applicable to the given type of product (see Table 2). Measurements and calculations of the seasonal space heating energy efficiency shall be made using the methodology of seasonal space heating energy efficiency of packages and in accordance with the procedures referred to in point (i). For solid fuel boiler heaters, the seasonal space heating energy efficiency shall be calculated in accordance with point (ii).
The water heating energy efficiency ηwh of combination heaters or package of space heaters containing one or more combination heaters shall not fall below 65 %. This criterion shall not apply to solid fuel boiler heaters.
The water heating energy efficiency shall be calculated in accordance with the procedures set out in Annex III to Regulation (EU) No 813/2013 and in Annex VII to Delegated Regulation (EU) No 811/2013.
The applicant shall declare that the product complies with this criterion and provide test results conducted in accordance with the testing procedure indicated in the EN standards (including transitional methods where applicable) applicable to the given type of product (see Table 2). Measurements and calculations shall be made using the methodology of water heating energy efficiency of packages in accordance with the procedures referred to in point (ii).
The greenhouse gas (GHG) emissions of the water-based heater, expressed in grams of CO2-equivalent per kWh of heating output calculated using the Total Equivalent Warming Impact (TEWI) formulas set out in Table 7, shall not exceed the values set out in Table 6.
Heat generator technology | GHG emission limits
All heaters, except heat pump heaters | 200 g CO2-equivalent/kWh heating output
Heat pump heaters | 150 g CO2-equivalent/kWh heating output
The GHG emissions shall be calculated following the TEWI formulae as set out in Table 7 (the formula depends on the heat generator technology). Each TEWI formula may consist of two parts, one depending solely on the heater efficiency (expressed in terms of the seasonal space heating energy efficiency, ηs) and the fuel carbon intensity (represented by the β parameter), and the second part (only applicable to heat pump heaters) depending on the greenhouse gas emissions due to refrigerant leakage. The GHG emissions from the refrigerant leakage depend on the global warming potential (GWP100) of the refrigerant and the refrigerant leakage during the use phase (expressed as an annual leakage rate, ER, in percentage of the total mass of the refrigerant per year) and at end-of-life (expressed as a percentage of the total mass of the refrigerant, α).
Heat generator technology | TEWI formula (g CO2-equivalent/kWh heating output)
Boiler heaters | βfuelηs
Heat pump heaters | δβfuel
ηs
1δβelec2,5ηsGWP100mERnαPhn
Cogeneration space heaters | βfuel
ηthermal
ηelβelec
ηthermal
Package of space heaters | 1SHPβfuel(1)
ηs,B
SHPδβfuel(2)
ηs,HP
1δβelec2,5ηs,HPGWP100mERnαPhn
The main parameters in the TEWI formulae set out in Table 7 are described in Table 8.
Parameter | Description of parameter | Units | Constant value or test to be performed in order to obtain the parameter
βelec | GHG emission intensity of electricity | [g CO2-equivalent/kWhelec] | 384
βfuel | GHG emission intensity of the fuel used by the heater | [g CO2-equivent/kWh] | See Table 9
ηs | Seasonal space heating energy efficiency | [-] | To be tested and declared by the applicant (Criterion 1)
ηs,B | Seasonal space heating energy efficiency of the boiler heater part for average climate conditions | [-] | To be tested and declared by the applicant; this corresponds to the seasonal space heating energy efficiency of the package minus supplementary heat pump, as stated in the product fiche of packages
ηs,HP | Seasonal space heating energy efficiency of the heat pump heater part for average climate conditions | [-] | To be tested and declared by the applicant; this corresponds to the seasonal space heating energy efficiency of the supplementary heat pump, as stated in the product fiche of packages
ηthermal | Thermal efficiency | [-] | See Table 10
ηel | Electrical efficiency | [-] | See Table 10
δ | Proxy | [-] |
= 0 if electrically-driven heat pump heater
= 1 if fuel-driven heat pump heater
GWP100 | Global warming potential (effect over 100 years) | [g CO2-equivalent/g refrigerant, over 100 year period] | Value declared by the applicant according Criterion 3
m | Refrigerant mass | [g] | To be declared by the applicant
ER | Refrigerant loss per year | [%/yr] | A value of ER = 3,5 %/yr shall be used.
n | Lifetime | [yr] | A value of n = 15 shall be used.
α | Refrigerant loss at end of life (disposal loss) | [%] | A value of α = 35 % shall be used.
P | Design load | [kW] | To be declared by the applicant.
h | Full load operating hours | [h/yr] | 2000
sHP | Share of heat output from the heat pump heater part over the total heat output | [-] |
= (16 — THP)/26
where THP is the temperature (°C) at which the (primary) heat pump efficiency equals the primary boiler efficiency. It is assumed that below this temperature the boiler fulfils the heat demand, while above this temperature the heat pump supplies the heat demand.
Table 9 describes how to evaluate parameter βfuel in the TEWI formulae depending on the fuel used by the heater. In case the boiler is designed for a fuel not listed in the table, the closest match of fuel shall be selected, based on the origin (fossil or biomass) and form (gaseous, liquid or solid) of the fuel used.
Fuel used by the heater | GHG emission intensity | Value (g CO2-equivalent/kWh)
Gaseous fossil fuels | βfuel = βgas | 202
Liquid fossil fuels | βfuel = βοil | 292
Solid fossil fuels | βfuel = βcoal | 392
Gaseous biomass | βfuel = βbio-gas | 98
Liquid biomass | βfuel = βbio-oil | 149
Wood logs | βfuel = βbio-log | 19
Wood chips | βfuel = βbio-chip | 16
Wood pellets | βfuel = βbio-pellet | 39
Blends of fossil fuels and biomass | βfuel = weighted average derived from the sum of the weight fractions of the individual fuels multiplied by their GHG emission parameter | Σ (Fuel X % × βfuelX) + (Fuel Y % × βfuelY) + … (Fuel N % × βfuelN)
Table 10 describes how to evaluate parameters ηthermal and ηel in the TEWI formula for cogeneration space heaters.
Where:
ηs means the seasonal space heating energy efficiency as defined in Regulation (EU) No 813/2013
ηel means the electrical efficiency as defined in Regulation (EU) No 813/2013
ηel,CHP100+Sup0 means the electrical efficiency at rated heat output of cogeneration space heater with supplementary heater disabled, as defined in Regulation (EU) No 813/2013
ηel,CHP100+Sup100 means the electrical efficiency at rated heat output of cogeneration space heater with supplementary heater enabled, as defined in Regulation (EU) No 813/2013
Parameter | Expression
ηthermal | ηthermalηs2,5ηel
ηel |
For cogeneration space heaters not equipped with supplementary heaters
ηelηel,CHP100Sup0
For cogeneration space heaters equipped with supplementary heaters
ηel0,85ηel,CHP100Sup00,15ηel,CHP100Sup100
A certificate signed by the manufacturer declaring compliance with this criterion shall be submitted to the awarding competent body, together with the relevant documentation. The applicant shall provide the calculated GHG emissions following the proposed TEWI formulae and detail all the parameters used to calculate the GHG emissions.
The global warming potential over a 100 year period (GWP100) of the refrigerant shall not exceed a value of 2000. GWP100 values shall be those set out in Annex I to Regulation (EC) No 842/2006. Sources of references for the GWP100 values should be those defined in Annex I.1(7) to Commission Regulation (EU) No 206/2012 [Commission Regulation (EU) No 206/2012 of 6 March 2012 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for air conditioners and comfort fans (OJ L 72, 10.3.2012, p. 7).].
In the case of space heaters using a secondary refrigerant, the design of these heaters shall not be based on secondary refrigerant, brine or additives classified as environmentally hazardous or constituting a health hazard within the meaning of Regulation (EC) No 1272/2008 of the European Parliament and of the Council [Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006 (OJ L 353, 31.12.2008, p. 1).] and Council Directive 67/548/EEC [Council Directive 67/548/EEC of 27 June 1967 on the approximation of laws, regulations and administrative provisions relating to the classification, packaging and labelling of dangerous substances (OJ 196, 16.8.1967, p. 1).], and installation instructions shall clearly indicate that substances classified as environmentally hazardous or constituting a health hazard shall not be used as a secondary refrigerant.
The names of refrigerant(s) used in the product shall be submitted with the application, along with their GWP100 values as defined in Regulation (EC) No 842/2006. The GWP100 values of refrigerants shall be calculated in terms of the 100-year warming potential of one kilogram of a gas relative to one kilogram of CO2. Sources of references for the GWP100 values should be those defined in Annex I.1(7) to Regulation (EU) No 206/2012.
The name(s) of the secondary refrigerant(s) used shall be submitted with the application.
The nitrogen oxide (NOx) content of the exhaust gas shall not exceed the limit values indicated in Table 11 (not applicable to electrical heaters). NOx emissions shall be measured as the sum of nitrogen monoxide and nitrogen dioxide and at the following operating conditions:
Gas and liquid heaters, at standard rating conditions and rated heat output
Solid fuel heaters, as seasonal space heating emissions according Table 4.
The unit of measurement shall be given in mg/kWh GCV energy input or in mg/Nm3, as appropriate.
Heat generator technology | NOx emission limit
Gas heaters |
Equipped with internal combustion engine: 170 mg/kWh GCV energy input
Equipped with external combustion: 36 mg/kWh GCV energy input
Liquid fuel heaters |
Equipped with internal combustion engine: 380 mg/kWh GCV energy input
Equipped with external combustion: 100 mg/kWh GCV energy input
Solid fuel heaters | 150 mg/Nm3 at 10 % O2