Directive 70/156/EEC is amended as follows:
In Annex IV, part I, a new item numbered 61, and footnote, is inserted as follows:
[Only for vehicles of category N1, class I as described in the first table in point 5.3.1.4 of Annex I to Directive 70/220/EEC as inserted by Directive 98/69/EC.’]
Subject
Directive No
Official Journal reference
Applicability
M1
M2
M3
N1
N2
N3
O1
O2
O3
O4
‘61. Air-conditioning system
(2006/40/EC)
L 161, 14.6.2006, p. 12
X
X
Annex XI is amended as follows:
in Appendix 1 a new item numbered 61 is inserted as follows:
Item
Subject
Directive No
M1 ≤ 2500 (1) kg
M1 > 2500 (1) kg
M2
M3
‘61
Air-conditioning system
2006/40/EC
X
X’
in Appendix 2 a new item numbered 61 is inserted as follows:
Item
Subject
Directive No
M1
M2
M3
N1
N2
N3
O1
O2
O3
O4
‘61
Air-conditioning system
2006/40/EC
X
W’
in Appendix 3 a new item numbered 61 is inserted as follows:
Item
Subject
Directive No
M2
M3
N1
N2
N3
O1
O2
O3
O4
‘61
Air-conditioning system
2006/40/EC
W’
in ‘Meaning of letters’ the following letter is added:
‘W Only for vehicles of category N1, class I as described in the first table in point 5.3.1.4. of Annex I to Directive 70/220/EEC as inserted by Directive 98/69/EC.’
The total GWP for a preparation is a weighted average, derived from the sum of the weight fractions of the individual substances multiplied by their GWPs.
Σ (Substance X % × GWP) + (Substance Y % × GWP) + … (Substance N % × GWP)
where % is the contribution by weight with a weight tolerance of +/- 1 %.
For example: applying the formula to a theoretical blend of gases consisting of 23 % HFC-32; 25 % HFC-125 and 52 % HFC-134a;
Σ (23 % × 550) + (25 % × 3400) + (52 % × 1300)
→ Total GWP = 1652,5.