The tables set out in this Annex, list construction products and/or materials which satisfy all of the requirements for the performance characteristic reaction to fire without need for testing.
[Mounted in accordance with EN ISO 9239-1, on a substrate of at least Class D - s2, d0 and with minimum density of 400 kg/m3 or with an air gap underneath.] [An interlayer of at least Class E and with maximum thickness 3 mm may be included in applications without an air gap, for parquet products with 14 mm thickness or more and for veneered floor coverings.] [Class as provided for in Commission Decision 2000/147/EC Annex Table 2.] [Type and quantity of surface coatings included are acrylic, polyurethane or soap, 50 - 100 g/m2, and oil, 20 - 60 g/m2.] [Conditioned according to EN 13238 (50 % RH 23 oC).] [Substrate at least Class A2 - s1, d0.] [Applies also to steps of stairs.]
Material, | Product detail |
Minimum mean density
(kg/m3)
Minimum overall thickness
(mm)
End-use condition | Class for floorings
Wood flooring and parquet | Solid flooring of oak or beech with surface coating |
Beech: 680
Oak: 650
8 | Glued to substrate | Cfl - s1
Solid flooring of oak, beech or spruce and with surface coating |
Beech: 680
Oak: 650
Spruce: 450
20 | With or without air gap underneath
Solid wood flooring with surface coating and not specified above | 390 | 8 | Without air gap underneath | Dfl - s1
20 | With or without air gap underneath
Wood parquet | Multilayer parquet with a top layer of oak of at least 5 mm thickness and with surface coating |
650
(top layer)
10 | Glued to substrate | Cfl - s1
14 | With or without air gap underneath
Multilayer parquet with surface coating and not specified above | 500 | 8 | Glued to substrate | Dfl - s1
10 | Without air gap underneath
14 | With or without air gap underneath
Veneered floor covering | Veneered floor covering with surface coating | 800 | 6 | Without air gap underneath | Dfl - s1
[Mounted mechanically on a wood batten support frame, with the gap closed or filled with a substrate of at least class A2 – s1, d0 with minimum density of 10 kg/m3 or filled with a substrate of cellulose insulation material of at least class E and with or without a vapour barrier behind. The wood product shall be designed to be mounted without open joints.] [Mounted mechanically on a wood batten support frame, with or without an open air gap behind. The wood product shall be designed to be mounted without open joints.] [Class as provided for in Table 1 of Annex to Delegated Regulation (EU) 2016/364.] [An open air gap may include possibility for ventilation behind the product, while a closed air gap will exclude such ventilation. The substrate behind the air gap must be of at least class A2 – s1, d0 with a minimum density of 10 kg/m3. Behind a closed air gap of maximum 20 mm and with vertical wood pieces, the substrate may be of at least class D – s2, d0.] [Joints include all types of joints e.g., butt joints and tongue and groove joints; Untreated wood is a wooden material that was not coated and was not subject to any kind of treatment other than kiln drying (physical, chemical, impregnation, or other treatments).] [Conditioned according to EN 13238.] [As illustrated in Figure a. Profiled area of the exposed side of the panel not more than 20 % of the plane area, or 25 % if measured at both exposed and unexposed side of the panel. For butt joints, the larger thickness applies at the joint interface.] [Rectangular wood pieces, with or without rounded corners, mounted horizontally or vertically on a support frame and surrounded by air on all sides, mainly used close to other building elements, both in interior and exterior applications.] [Maximum exposed area (all sides of rectangular wood pieces and wood support frame) not more than 110 % of the total plane area, see Figure b.] [Other building elements closer than 100 mm from the wood ribbon element (excluding its support frame) must be of at least class A2 – s1, d0, at distances 100–300 mm of at least class B – s1, d0 and at distances more than 300 mm of at least class D – s2, d0.] [Applies also to staircase risers.]
Product | Product detail | Minimum mean density (kg/m3) | Minimum thicknesses, total/minimum (mm) | End-use condition | Class
Panelling and cladding | Untreated wood pieces with or without tongue and groove and with or without profiled surface | 390 | 9/6 | Without air gap or with closed air gap behind | D – s2, d2
12/8 | D – s2, d0
Panelling and cladding | Untreated wood pieces with or without tongue and groove and with or without profiled surface | 390 | 9/6 | With open air gap ≤ 20 mm behind | D – s2, d0
18/12 | Without air gap or with open air gap behind
Wood ribbon elements | Untreated wood pieces mounted on a support frame | 390 | 18 | Surrounded by open air on all sides | D – s2, d0
nnumber of wood pieces per metre
tthickness of each wood piece, in metre
wwidth of each wood piece, in metre