Adaptation of provisions of the Annex to the Torremolinos Protocol for application of Article 3(1) of Directive 97/70/EC
For the purpose of this Annex:
"New fishing vessel built on or after 1 January 2003" means a new fishing vessel for which:
on or after 1 January 2003 the building or major conversion contract is placed; or
the building or major conversion contract has been placed before 1 January 2003, and which is delivered three years or more after that date; or
in the absence of a building contract, on or after 1 January 2003:
the keel is laid, or
construction identifiable with a specific ship begins, or
assembly has commenced comprising at least 50 tonnes or 1 % of the estimated mass of all structural material, whichever is less.
PART A
Adaptations applicable to all fishing vessels to which the Directive applies, except to new fishing vessels built on or after 1 January 2003
CHAPTER I: GENERAL PROVISIONS
Regulation 2: Definitions
Paragraph (1) "New vessel" has to be replaced by the definition of "new fishing vessel" contained in Article 2 to this Directive.
CHAPTER V: FIRE PROTECTION, FIRE DETECTION, FIRE EXTINCTION AND FIRE FIGHTING
Regulation 2: Definitions
Paragraph (2) "standard fire test" to be read with the following changes at the end with regard to the standard temperature curve: "... The standard time-temperature curve is defined by a smooth curve drawn through the following internal furnace temperature points:
>TABLE>"
CHAPTER VII: LIFE-SAVING APPLIANCES AND ARRANGEMENTS
Regulation 1: Application
Paragraph (2) to be read as follows: "Regulations 13 and 14 shall also apply to existing vessels of 45 metres in length and over, provided that the administration may defer the implementation of the requirements of these regulations until 1 February 1999."
Regulation 13: Radio life-saving appliances
Paragraph (2) to be read as follows: "Two-way VHF radiotelephone apparatus provided on board existing vessels and not complying with the performance standards adopted by the organisation may be accepted by the administration until 1 February 1999, provided that the administration is satisfied that they are compatible with approved two-way VHF radiotelephone apparatus."
CHAPTER IX: RADIO COMMUNICATIONS
Regulation 1: Application
Paragraph (1), second sentence, to be read as follows: "However, for existing vessels, the administration may defer the implementation of the requirements until 1 February 1999."
Regulation 3: Exemptions
Paragraph (2)(c) to be read as follows: "when the vessel will be taken permanently out of service before 1 February 2001."
PART B
Adaptation applicable to new fishing vessels built on or after 1 January 2003
The existing text of the following regulations shall be read as follows:
CHAPTER I: GENERAL PROVISIONS
Regulation 2: Definitions
Subparagraph (22)(a)(ii)
The bulkhead shall be located at a distance from the forward perpendicular: not less than 0,05L and not more than 0,05L plus 1,35 m for vessels of less than 45 m in length.
Regulation 6: Surveys
Subparagraph (1)(c)
In addition to the periodical survey required in subparagraph (b)(i), intermediate surveys with regard to the structure and machinery of the vessel at intervals of two years plus/minus three months for vessels constructed of material other than wood and at intervals specified by the Administration for vessels constructed of wood. The surveys shall also be such as to ensure that alterations, which would adversely affect the safety of the vessel or the crew, have not been made.
CHAPTER II: CONSTRUCTION, WATERTIGHT INTEGRITY AND EQUIPMENT
Regulation 1: Construction
Paragraph (1)
Strength and construction of hull, superstructures, deckhouses, machinery casings, companionways and any other structures and vessel's equipment shall be sufficient to withstand all foreseeable conditions of the intended service and shall be in accordance with the rules of a recognised organisation.
Regulation 2: Watertight doors
Paragraph (1)
The number of openings in watertight bulkheads, as required by regulation 1(3), shall be reduced to the minimum compatible with the general arrangements and operational needs of the vessel; openings shall be fitted with watertight closing appliances complying with the rules of a recognised organisation. Watertight doors shall be of an equivalent strength to the adjacent unpierced structure.
Regulation 2: Watertight doors
Subparagraph (3)(a)
In vessels of 45 m in length and over, watertight doors shall be of the sliding type in:
spaces where it is intended to open them at sea and if located with their sills below the deepest operating waterline, unless the Administration considers it to be impracticable or unnecessary taking into account the type and operation of the vessel.
Exemptions from this regulation allowed by a Member State shall be subject to the procedure of Article 4 of this Directive.
Regulation 5: Hatchways
Paragraph (3)
Arrangements for securing wood hatchway covers weathertight shall be provided in accordance with the standards as given in regulations 14 and 15 of Annex I to the International Convention on Load Lines 1966(1).
Regulation 9: Ventilators
Paragraph (1)
In vessels of 45 m in length and over, the height above deck of ventilator coamings, other than machinery space ventilator coamings, shall be at least 900 mm on the working deck and at least 760 mm on the superstructure deck. In vessels of less than 45 m in length the height of these coamings shall be 760 mm and 450 mm respectively. The height above deck of machinery space ventilator openings, necessary to continuously supply the machinery space and, on demand, immediately supply the generator room, in general shall be in compliance with regulation II/9(3). However, where due to the ships size and arrangements this is not practicable, lesser heights, but in all cases not less than 900 mm above the working deck and the superstructure deck, may be accepted with the provision of weathertight closing appliances in accordance with regulation II/9(2) in combination with other suitable arrangements to ensure an uninterrupted adequate supply of ventilation to the spaces.
Regulation 12: Side scuttles
Paragraph (6)
The Administration may accept side scuttles and windows without deadlights in side and aft bulkheads of deckhouses located on or above the working deck if satisfied that the safety of the vessel will not be impaired, taking into account the rules of recognised organisations based upon the relevant ISO standards.
Regulation 15: Anchor equipment
Anchor equipment designed for quick and safe operation shall be provided, which shall consist of anchoring equipment, anchor chains or wire ropes, stoppers and a windlass or other arrangements for dropping and hoisting the anchor and for holding the vessel at anchor in all foreseeable service conditions. Vessels shall also be provided with adequate mooring equipment for safe mooring in all operating conditions. Anchor and mooring equipment shall be in accordance with the rules of a recognised organisation.
CHAPTER III: STABILITY AND ASSOCIATED SEAWORTHINESS
Regulation 1: General
Vessels shall be so designed and constructed that the requirements of this chapter will be satisfied in the operating conditions referred to in regulation 7. Calculations of the righting lever curves shall be carried out in accordance with the IMO Code on Intact Stability for All Types of Ships(2).
Regulation 2: Stability criteria
Paragraph (1)
The following minimum stability criteria shall be met unless the Administration is satisfied that operating experience justifies departures therefrom. Any departure from the required minimum stability criteria, allowed by a Member State, shall be subject to the procedure of Article 4 of this Directive(3).
Subparagraph (1)(d)
The initial metacentric height GM shall not be less than 350 mm for single deck vessels. In vessels with complete superstructure the metacentric height may be reduced to the satisfaction of the Administration but in no case shall be less than 150 mm. Reduction of the required metacentric height, allowed by a Member State, shall be subject to the procedure of Article 4 of this Directive.
Paragraph (3)
Where ballast is provided to ensure compliance with paragraph (1), its nature and arrangements shall be to the satisfaction of the Administration. In vessels with a length of less than 45 m, such ballast shall be permanent. Where ballast is permanent, it shall be solid and fixed securely in the vessel. The Administration may accept liquid ballast, stored in completely filled tanks which are not connected to any pumping system of the vessel. If liquid ballast is used as permanent ballast to ensure compliance with paragraph (1), details shall be included in the Certificate of Compliance and in the stability booklet.
Permanent ballast shall not be removed from the ship or relocated without the approval of the Administration.
Regulation 4: Particular fishing methods
Vessels engaged in particular fishing methods where additional external forces are imposed on the vessel during fishing operations, shall meet the stability criteria of regulation 2(1) increased, if necessary, to the satisfaction of the Administration. Vessels engaged in beam trawling shall comply with the following increased stability criteria:
the criteria for the area's under the righting lever and for the righting levers as given in regulation 2(1)(a) and (b) shall be increased by 20 %;
the metacentric height shall not be less than 500 mm;
the criteria as given under (a) shall be applicable only to vessels with an installed propulsion power not exceeding the value in kilowatts as given in the following formulas:
N = 0,6 Ls2 for vessels with a length of 35 m or less, and
N = 0,7 Ls2 for vessels with a length of 37 m and over,
at intermediate length of the vessel the coefficient for Ls has to be obtained by interpolation in between 0,6 and 0,7,
Ls is the overall length according to the Tonnage Certificate.
If the installed propulsion power exceeds the values for the standard propulsion power as given in the above formulas the criteria as mentioned under (a) shall be increased directly proportional to the higher propulsion power.
The Administration shall be satisfied that the above increased stability criteria for beam trawlers are met in the operating conditions mentioned under regulation 7(1) of this chapter.
For the calculation of the stability, the beams shall be assumed to be hoisted up to an angle of 45 degrees with the horizontal.
Regulation 5: Severe wind and rolling
Vessels shall be able to withstand the effect of severe wind and rolling in associated sea conditions taking account of the seasonal weather conditions, the sea states in which the vessel will operate, the type of vessel and its mode of operation. The relevant calculations shall be carried out in accordance with the IMO Code on Intact Stability for all Types of Ships.
Regulation 8: Ice accretion
This regulation applies except where the modification of the icing allowance, left to the discretion of the Administration by recommendation 2(4) is not allowed.
Regulation 9: Inclining test
Paragraph (2)
Where alterations are made to a vessel affecting its light ship condition and/or the position of the centre of gravity, the vessel shall, if the Administration considers this necessary taking into account the vessels stability margins, be reinclined and the stability information revised. However, if the lightweight variation exceeds 2 % from the original lightweight and it cannot be demonstrated by calculation that the vessel continues to comply with the stability criteria, the vessel shall be re-inclined.
Regulation 12: Bow height
The bow height shall be sufficient, to prevent the excessive shipping of water.
For vessels operating in restricted areas not more than 10 miles from the coast, the minimum bow height shall be to the satisfaction of the Administration and be determined taking into account the seasonal weather conditions, the sea states in which the vessel will operate, the type of the vessel and its mode of operation.
For vessels operating in all other areas:
where, during the fishing operations, the catch has to be stowed into the fish holds via hatchways, which are situated on a exposed working deck forward of the deckhouse or superstructure, the minimum bow height shall be calculated in accordance with the method of calculation, contained in recommendation 4 of attachment 3 to the Final Act of the Torremolinos conference;
where the catch has to be stowed into the fish holds via a hatchway, which is situated on an exposed working deck, protected by a deckhouse or superstructure, the minimum bow height shall be in accordance with regulation 39 of Annex I to the International Load Line Convention 1966, but shall not be less than 2000 mm. In this respect the maximum permissible operating draught is to be regarded in place of the assigned summer freeboard.
Regulation 14: Subdivision and damage stability
Vessels of 100 m in length and over, where the total number of persons carried is 100 or more, shall be capable, of remaining afloat with positive stability, after flooding of any compartment assumed damaged, having regard to the type of vessel, the intended service and area of operation(5). Calculations to be carried out in accordance with the guidance as mentioned in the footnote.
CHAPTER IV: MACHINERY AND ELECTRICAL INSTALLATIONS AND PERIODICALLY UNATTENDED MACHINERY SPACES
Regulation 3: General
Paragraph (1)
Main propulsion, control, steam pipe, fuel oil, compressed air, electrical and refrigeration systems; auxiliary machinery; boilers and other pressure vessels; piping and pumping arrangements; steering equipment and gears, shafts and couplings for power transmission shall be designed, constructed, tested, installed and serviced in accordance with the rules of a recognised organisation. This machinery and equipment, as well as lifting gear, winches, fish handling and fish processing equipment shall be protected so as to reduce to a minimum any danger to persons on board. Special attention shall be paid to moving parts, hot surfaces and other dangers.
Paragraph (7)
The Administration shall be satisfied that regulations 16 to 18 are uniformly implemented and applied in accordance with the rules of a recognised organisation(6).
Paragraph (9)
Measures shall be taken to the satisfaction of the Administration to ensure that all equipment is functioning in a reliable manner in all operating conditions, including manoeuvring, and that arrangements in accordance with the rules of a recognised organisation are made for regular inspections and routine tests to ensure continuous reliable operation.
Paragraph (10)
Vessels shall be provided with documentary evidence, complying with the rules of a recognised organisation, of their fitness to operate with periodically unattended machinery spaces.
Regulation 6: Steam boilers, feed systems and steam piping arrangements
Paragraph (1)
Every steam boiler and every unfired steam generator shall be provided with not less than two safety valves of adequate capacity. However, the Administration may, having regard to the output or any other features of any steam boiler or unfired steam generator, permit only one safety valve to be fitted if satisfied that adequate protection against overpressure is thereby provided in accordance with the rules of a recognised organisation.
Regulation 8: Wheelhouse control
Subparagraph (1)(b)
Where remote control of propulsion machinery is provided from the wheelhouse, the following shall apply: the remote control referred to in subparagraph (a) shall be performed by means of a control device complying with the rules of a recognised organisation with, where necessary, means of preventing overload of the propulsion machinery.
Regulation 10: Arrangements for fuel oil, lubricating oil and other flammable oils
Paragraph (4)
Fuel oil pipes which, if damaged, would allow oil escape from a storage, settling or daily service tank situated above the double bottom, shall be fitted with a cock or valve on the tank capable of being closed from a safe position outside the space concerned in the event of a fire arising in the space in which such tanks are situated. In the special case of deep tanks situated in any shaft or pipe tunnel or similar space, valves on the tank shall be fitted but control in the event of fire may be effected by means of an additional valve on the pipe or pipes outside the tunnel or similar space. If such additional valve is fitted in the machinery space, it shall be capable of being operated outside this space.
Paragraph (7)(a)
Fuel oil pipes and their valves and fittings shall be steel or other equivalent material, provided that a minimum of flexible pipes may be used. Such flexible pipes and end attachments shall be of adequate strength and shall be constructed of approved fire resistant material or have fire-resistant coatings in accordance with the rules of a recognised organisation. Fitting of those flexible pipes shall be in accordance with the IMO MSC. Circ. 647 "Guidelines to minimise leakages from flammable liquid systems".
Paragraph (10)
The arrangements for the storage, distribution and use of oil employed in pressure lubrication systems shall be in accordance with the rules of a recognised organisation. Such arrangements in machinery spaces of category A and, wherever practicable, in other machinery spaces shall at least comply with the provisions of paragraphs (1), (3), (6) and (7) and in so far as necessary, in accordance with the rules of a recognised organisation, with paragraphs (2) and (4). This does not preclude the use of sight flow glasses in lubrication systems provided they are shown by test to have a suitable degree of fire resistance.
Paragraph (11)
The arrangements for the storage, distribution and use of flammable oils employed under pressure in power transmission systems other than oil referred to in paragraph (10) in control and activating systems and heating systems shall be in accordance with the rules of a recognised organisation. In locations where means of ignition are present such arrangements shall at least comply with the provisions of paragraphs (2) and (6) and with the provisions of paragraphs (3) and (7) in respect of strength and construction.
Regulation 12: Protection against noise
Measures shall be taken to reduce the effects of noise upon personnel in machinery spaces to levels as given in the IMO Code on Noise Levels on Board Ships(7).
Regulation 13: Steering gear
Paragraph (1)
Vessels shall be provided with a main steering gear and an auxiliary means of actuating the rudder in compliance with the rules of a recognised organisation. The main steering gear and the auxiliary means of actuating the rudder shall be arranged so that so far as is reasonable and practicable a single failure in one of them will not render the other one inoperative.
Regulation 16: Main source of electrical power
Subparagraph (1)(a)
Where electrical power constitutes the only means of maintaining auxiliary services essential for the propulsion and the safety of the vessel, a main source of electrical power shall be provided which shall include at least two generating sets, one of which may be driven by the main engine. In accordance with the rules of a recognised organisation other arrangements having equivalent electrical capability may be accepted.
CHAPTER V: FIRE PROTECTION, FIRE DETECTION, FIRE EXTINCTION AND FIRE FIGHTING
Regulation 1: General
Subparagraph (c)
Method IIIF: The fitting of an automatic fire alarm and detection system in all spaces in which a fire might be expected to originate, generally with no restriction on the type of internal divisional bulkheads, except that in no case shall the area of any accommodation space or spaces bounded by an "A" or "B" class division exceed 50 m2. However, the Administration may increase this area for public spaces up to 75 m2.
Regulation 2: Definitions
Paragraph (1)
"Non-combustible material" means a material which neither burns nor gives off flammable vapours in sufficient quantity for self-ignition when heated to approximately 750 °C, this being determined in accordance with the IMO Fire Test Procedures Code(8). Any other material is a combustible material.
Paragraph (2) "standard fire test" to be read as follows:
"A standard fire test" is one in which the specimens of the relevant bulkheads or decks are exposed in a test furnace to temperatures corresponding approximately to the standard temperature curve. The test methods shall be in accordance with the IMO Fire Test Procedures Code.
Paragraph (3) (last sentence)
The Administration shall require a test of a prototype bulkhead or deck to ensure that it meets the above requirements for integrity and temperature rise in accordance with the IMO Fire Test Procedures Code.
Paragraph (4) (last sentence)
The Administration shall require a test of a prototype division to ensure that it meets the above requirements for integrity and temperature rise in accordance with the IMO Fire Test Procedures Code.
Paragraph (6) (last sentence)
The Administration shall require a test of a prototype division to ensure that it meets the above requirement for integrity and temperature rise in accordance with the IMO Fire Test Procedures Code.
Paragraph (9)
Low flame spread means that the surface thus described will adequately restrict the spread of flame, this being determined in accordance with the IMO Fire Test Procedures Code.
Regulation 4: Bulkheads within the accommodation and service spaces
Paragraph (4)
Method IIIF: There shall be no restriction on the construction of bulkheads not required by this or other regulations of this part to be "A" or "B" class divisions. In no case shall the area of any accommodation space or spaces bounded by a continuous "A" or "B" class division exceed 50 m2, except in individual cases where "C" class bulkheads are required in accordance with table 1 in regulation 7. However, the Administration may increase this area for public spaces up to 75 m2.
Regulation 7: Fire integrity of bulkheads and decks
Last note to tables
(*) Where an asterisk appears in the tables the division is required to be of steel or equivalent material but is not required to be of "A" class standard.
Where a deck is penetrated for the passage of electrical cables, pipes and vent ducts, such penetrations shall be made tight to prevent the passage of flame and smoke.
Regulation 8: Details of construction
Paragraph (3), Methods IF, IIF and IIIF