the location of the site with regard to other Member States giving the distances from frontiers and closest conurbations, together with their populations.
1.2. Hydrology
For an installation situated near to a water body providing a potential contamination pathway to another Member State, a brief description of appropriate hydrological features, extending to the other Member State(s), for example:
brief description of the path(s), tributaries, estuary, water abstraction, flood plains, etc.
average, maximum and minimum water flows and their frequency of occurrence
underground water table, levels and flows
brief description of the littoral areas
direction and force of currents, tides, circulation patterns, both local and regional
flood risk and protection of the installation.
1.3. Meteorology
Local climatology with frequency distributions of:
wind directions and speeds
precipitation intensity and duration
for each wind sector, atmospheric dispersion conditions, duration of temperature inversions.
1.4. Natural resources and foodstuffs
Brief description of:
soil characteristics and ecological features of the region
water utilisation in the region and as appropriate in neighbouring Member States
principal food resources in the region and as appropriate in other Member States: crops, stock breeding, fishing, hunting and, for discharges into sea, data on fishing in territorial and extraterritorial waters
foodstuff distribution system and particularly the export to other Member States from the regions concerned, in so far as they are related to the risk of exposure from discharges through the significant exposure pathways.
The installation
2.1. Brief description and history of the installation to be dismantled
2.2. Ventilation systems and the treatment of gaseous and airborne wastes
Description of ventilation, decay, filtration and discharge systems, in normal conditions and in the case of an accident, including flow diagrams
2.3. Liquid waste treatment
Description of liquid waste treatment facilities, storage capacities and discharge systems, including flow diagrams
2.4. Solid waste treatment
Description of solid waste treatment facilities and storage capacities
2.5. Containment
Description including leaktightness specification and testing
Release from the installation of airborne radioactive effluents in normal conditions
3.1. Authorisation procedure in force
outline of the procedure in force