Specific safety requirements (Article 3(4)) CHAPTER II: CONSTRUCTION, WATERTIGHT INTEGRITY AND EQUIPMENT Add followingnew Regulations: ‘Regulation 16: Working decks within an enclosed superstructure 1. Such decks shall be fitted with an efficient drainage system having an appropriate drainage capacity to dispose of washing water and fish guts.
All openings necessary for fishing operations shall be provided with means for quick and efficient closure by one person.
Where the catch is brought on to such decks for handling or processing, the catch shall be placed in a pound. Such pounds shall comply with Regulation 11 of Chapter III. An efficient drainage system shall be fitted.
Adequate protection against inadvertent influx of water to the working deck shall be provided.
At least two exits from such decks shall be provided.
The clear headroom in the workingspace shall at all points be not less than two metres.
A fixed ventilation system providingat least six changes of air per hour shall be provided.
Regulation 17: Draught marks 1. All ships shall be provided with draught marks in decimetres on the stem and the stern on both sides.
Such marks shall be placed as close as practicable to the perpendiculars.
Regulation 18: Tanks for fish in refrigerated (RSW) or chill.ed (CSW) sea water 1. If RSW- or CSW-tanks or similar tank systems are used, such tanks shall be provided with a separate, permanently fitted arrangement for the filling and emptyingof seawater.
If such tanks are to be used also for carryingdry cargo, the tanks shall be arranged with a bilge system and provided with adequate means to avoid ingress of water from the bilge system into the tanks.' CHAPTER III: STABILITY AND ASSOCIATED SEAWORTHINESS Regulation 9: Inclining test Add followingnew paragraph 4: ‘4. The incliningtest and determination of conditions required by Regulation III/9(1) shall be performed at least every 10 years.' CHAPTER IV: MACHINERY AND ELECTRICAL INSTALLATIONS AND PERIODICALLY UNATTENDED MACHINERY SPACES Regulation 13: Steering gear Add followingtext to paragraph 10: ‘If this power source is electrical, the emergency source of electrical power shall be capable of servingthe auxiliary means for activatingthe rudder for a period of at least 10 minutes.' Regulation 16: Main source of electrical power Add followingparagraph 3: ‘3. Navigation lights, if solely electrical, shall be supplied through their own separate switchboard and adequate means for the monitoringof such lights shall be provided.'
Regulation 17: Emergency source of electrical power Notwithstanding paragraph 2, for vessels of a length of 45 metres and over, the emergency source of electrical power shall be capable of serving the installations listed in that Regulation for a period of not less than eight hours.
CHAPTER V: FIRE PROTECTION, FIRE DETECTION, FIRE EXTINCTION AND FIRE FIGHTING Regulation 22: Fire-extinguishing appliances in machinery spaces Notwithstandingthe provisions of this Regulation, all machinery spaces of category A shall be fitted with a fixed fire-extinguishing arrangement.
Regulation 40: Fire-extinguishing appliances in machinery spaces Notwithstandingthe provisions of this Regulation, all machinery spaces of category A shall be fitted with a fixed fire-extinguishing arrangement.