1 ANNEX, Directive (EU) 1982/434

In forcesince 10 Apr 1990
I.

IDENTIFICATION OF OXIDIZING AGENTS AND DETERMINATION OF HYDROGEN PEROXIDE IN HAIR-CARE PRODUCTS PURPOSE AND SCOPE The iodometric determination of hydrogen peroxide in cosmetics is only possible in the absence of other oxidizing agents that form iodine from iodides.

Consequently, before the iodometric determination of hydrogen peroxide it is necessary to detect and identify any other oxidizing agents present. This identification breaks down into two stages; the first covers the persulphates, the bromates and hydrogen peroxide and the second covers barium peroxide.

A. IDENTIFICATION OF PERSULPHATES, BROMATES AND HYDROGEN PEROXIDE 1. PRINCIPLE Sodium persulphate, potassium persulphate and ammonium persulphate; potassium bromate, sodium bromate and hydrogen peroxide — whether or not originating from barium peroxide — are identified by means of descending paper chromatography, use being made of two developing solvent.

2.

REAGENTS All reagents should be of analytical purity.

2.1. 0·5 % (m/v) aqueous reference solutions of the following compounds:

2.1.1. Sodium persulphate 2.1.2. Potassium persulphate 2.1.3. Ammonium persulphate 2.1.4. Potassium bromate 2.1.5. Sodium bromate 2.1.6. Hydrogen peroxide 2.2. Developing solvent A, 80 % (v/v) ethanol 2.3. Developing solvent B, benzene — methanol — 3-methyl butan-1-ol — water (34:38:18:10 by vol) 2.4. Detecting agent A, 10 % (m/v) aqueous solution of potassium iodide 2.5. Detecting agent B, 1 % (m/v) aqueous solution of starch 2.6. Detecting agent C, 10 % (m/m) hydrochloric acid 2.7. 4N hydrochloric acid 3. APPARATUS AND EQUIPMENT 3.1. Chromatography paper (Whatman paper No 3 and No 4 or their equivalents) 3.2. Micropipette, 1 µl 3.3. Standard flasks, 100 ml 3.4. Fluted filters 3.5. Apparatus for descending paper chromatography 4. SAMPLE PREPARATION 4.1. Water soluble products Make two solutions of eachsample by dissolving 1 g and 5 g of the product respectively in 100 ml of water. Use 1 µl of eachof these solutions for carrying out the paper chromatography described in Section 5.

4.2. Products sparingly soluble in water 4.2.1. Weighout 1 g and 5 g of the sample and disperse in 50 ml of water, make up to 100 ml withwater in eachcase and mix. Filter the two dispersions over a fluted filter (3.4) and use 1 µl of eachof the filtrates in order to carry out the paper chromatography described in Section 5.

4.2.2. Prepare once again two dispersions of eachsample by dispersing 1 g and 5 g in 50 ml of water, acidify with dilute hydrochloric acid (2.7), make up with water to 100 ml and mix. Filter the dispersions through a fluted filter (3.4) and use 1 µl of the two filtrates in order to carry out the paper chromatography described in Section 5.

4.3. Creams Disperse 5 g and 20 g of eachproduct in 100 ml of water and use the dispersions to carry out the paper chromatography described in Section 5.

5.

METHOD 5.1. Put an appropriate quantity of solvents A (2.2) and B (2.3) into two separate chromatography tanks in order to carry out the descending paper chromatography. Saturate the chromatography tanks for at least 24 hours with solvent vapour.

5.2. Apply 1 µl of one sample solution and of one reference solution prepared according to Sections 4 and 2.1 to eachstarting point on a strip of chromatography paper (Whatman No 3 or equivalent) 40 cm long and 20 cm wide (3.1) or another suitable format and evaporate the solution in air.

5.3. Place the chromatography strip (5.2) in the chromatography tank filled with developing solvent A (5.1) and develop until the solvent front has advanced 35 cm (about 15 hours).

5.4. Repeat the procedure described in Sections 5.2 and 5.3, using chromatography paper (Whatman No 4 or equivalent) (3.1) and developing solvent B. Chromatograph until the solvent front has advanced 35 cm (about five hours).

5.5. After development remove the chromatograms and dry them in air.

5.6. Reveal the spots in the chromatogram by spraying it successively with:

5.6.1. detecting agent A (2.4) followed shortly thereafter by detecting agent B (2.5). The spots of the persulphates will now appear first in the chromatogram and will be followed by the hydrogen peroxide spots. Mark the spots witha pencil;

5.6.2. detecting agent C (2.6) on the chromatograms obtained in accordance withSection 5.6.1; the presence of bromates will now be indicated by greyish blue spots in the chromatogram.

5.7. Under the abovementioned conditions pertaining to developing solvents A (2.2) and B (2.3), the Rf values of the reference substances (2.1) are approximately as follows:

Developing solvent A (2.2) Developing solvent B (2.3) Sodium persulphate 0·40 0·10 Potassium persulphate 0·40 0·02 + 0·05 Ammonium persulphate0·50 0·10 + 0·20 Sodium bromate 0·40 0·20 Potassium bromate 0·40 0·10 + 0·20 Hydrogen peroxide 0·80 0·80

B. IDENTIFICATION OF BARIUM PEROXIDE 1. PRINCIPLE Barium peroxide is identified by the formation of hydrogen peroxide after acidification of the sample (A.4.2), and by the presence of the barium ion: — in the absence of persulphates (A), by adding dilute sulphuric acid to a portion of the acid sample solution (B.4.1) as a result of which a white precipitate of barium sulphate is formed. The presence of barium ions in the sample (B.4.1) is again confirmed by paper chromatography in the manner described below (B.5), — where barium peroxide and persulphates are present simultaneously (B.4.2) by digesting the residue from the solution (B.4.2) in an alkali; after dissolution in hydrochloric acid, the presence of barium ions is confirmed in the solution of the melt (B.4.2.3) by paper chromatography and/or by barium sulphate precipitation.

2.

REAGENTS 2.1. Methanol 2.2. 36 % (m/m) concentrated hydrochloric acid 2.3. 6N hydrochloric acid 2.4. 4N sulphuric acid 2.5. Rhodizonic acid disodium salt 2.6. Barium chloride (BaCl2 · 2H2 O) 2.7. Anhydrous sodium carbonate 2.8. 1 % (m/v) aqueous solution of barium chloride 2.9. Developing solvent consisting of methanol, concentrated hydrochloric acid (concentration 36 %) and water (80: 10: 10 by vol) 2.10. Detecting agent, 0·1 % (m/v) aqueous solution of rhodizonic acid disodium salt, to be freshly prepared immediately before use.

3.

APPARATUS AND EQUIPMENT 3.1. Micropipette, 5 µl 3.2. Platinum crucibles 3.3. Standard flasks, 100 ml 3.4. Chromatography paper Schleicher and Schull 2043 b or equivalent.

Clean the paper by developing it overnight in a descending chromatography tank (A.3.5) containing developing solvent (B.2.9) and then dry.

3.5. Fluted filter paper 3.6. The usual apparatus for carrying out ascending paper chromatography 4. SAMPLE PREPARATION 4.1. Products in which persulphate are absent 4.1.1. Disperse 2 g of the product in 50 ml of water and bring the pH of the dispersion to about 1 with hydrochloric acid (B.2.3) 4.1.2. Transfer the dispersion with water into a 100-ml standard flask, make up to the mark with water and mix. Use this dispersion for the paper chromatography analysis described in Section 5 and for identification of barium by precipitation of the sulphate.

4.2. Products in which persulphates are present 4.2.1. Disperse 2 g of the product in 100 ml of water and filter.

4.2.2. Add to the dried residue seven to 10 times its weight of sodium carbonate (B.2.7), mix and melt the mixture in a platinum crucible (B.3.2) for half an hour.

4.2.3. Cool to room temperature, dissolve the melt in 50 ml of water and filter (B.3.5) 4.2.4. Dissolve the residue from the melt in hydrochloric acid (B.2.3) and make up to 100 ml with water. Use this solution for the paper chromatography analysis described in Section 5 and for the identification of barium by precipitation of the sulphate.

5.

METHOD 5.1. Place an appropriate quantity of developing solvent (B.2.9) in a tank for ascending paper chromatography and saturate the tank for at least 15 hours.

5.2. On a piece of chromatography paper — pretreated as described in Section B.3.4 — apply 5 µl of eachof the solutions prepared in accordance withSections B.4.1.2 and B.4.2.4 and reference solution B.2.8 at three starting points.

5.3. Dry the sample and reference spots in air. Develop the chromatogram until the solvent front has ascended 30 cm.

5.4. Remove the chromatogram from the tank and dry in air.

5.5. Reveal the spots on the chromatogram by spraying the paper with detecting agent B.2.10. In the presence of the barium, red spots with an RF value of about 0·10 appear on the chromatogram.

C. DETERMINATION OF HYDROGEN PEROXIDE 1. PRINCIPLE The iodometric determination of hydrogen peroxide is based on the following reaction:

H2 O2 + 2H+ + 2I− → I2 − 2H2O This conversion proceeds slowly but can be accelerated by the addition of ammonium molybdate. The iodine formed is determined titrimetrically against sodium thiosulphate and is a measure of the hydrogen peroxide content.

2.

DEFINITION The hydrogen peroxide content measured in the manner described below is expressed as a percentage by mass (% m/m) of the product.

3.

REAGENTS All reagents should be of analytical purity.

3.1. 2N sulphuric acid 3.2. Potassium iodide 3.3. Ammonium molybdate 3.4. 0·1N sodium thiosulphate 3.5. 10 % (m/v) potassium iodide solution, to be freshly prepared immediately before use 3.6. 20 % (m/v) ammonium molybdate solution 3.7. 1 % (m/v) starchsolution 4. APPARATUS AND EQUIPMENT 4.1. Beakers, 100 ml 4.2. Burette, 50 ml 4.3. Standard flasks, 250 ml 4.4. Measuring cylinders, 25 and 100 ml 4.5. One-mark pipettes, 10 ml

4.6. Conical flasks, 250 ml 5. METHOD 5.1. Into a 100-ml beaker weighout 10 g (m gram) of the product, containing about 0·6 g of hydrogen peroxide. Transfer the contents withwater into a 250-ml standard flask, make up to the mark with water and mix.

5.2. Pipette 10 ml of the sample solution (5.1) into a 250-ml conical flask (4.6) and add successively 100 ml of 2N sulphuric acid (3.1), 20 ml of potassium iodide solution (3.5) and three drops of ammonium molybdate solution (3.6).

5.3. Titrate the iodine formed immediately against 0·1N sodium thiosulphate solution (3.4) and just before the end point is reached add a few millilitres of starchsolution as indicator (3.7). Record the consumption of 0·1N sodium thiosulphate (3.4) in millilitres (V).

5.4. In the manner described in Sections 5.2 and 5.3, carry out a blank determination, replacing the 10 ml of the sample solution by 10 ml of water. Record the consumption of 0·1N sodium thiosulphate in the blank determination (Vo ml).

6.

CALCULATION Calculate the hydrogen peroxide content of the product as a percentage by mass (% m/m) with the aid of the following formula: % hydrogen peroxide ¼ ð Þ V Vo 1 7008 250 100 m 10 1 000 ¼ ð Þ V Vo 4 252 m in which: m = the quantity in grams of product analyzed (5.1), Vo = the consumption in millilitres of 0·1N thiosulphate solution in the blank determination (5.4), V = the consumption in millilitres of 0·1N thiosulphate solution in the titration of the sample solution (5.3).

7.

REPEATABILITY (1 ) For a product containing about 6 % m/m hydrogen peroxide the difference between the results of two determinations in parallel carried out on the same sample should not exceed an absolute value of 0·2 %.

II.

IDENTIFICATION AND SEMI-QUANTITATIVE DETERMINATION OF CERTAIN OXIDATION COLORANTS IN HAIR DYES 1. PURPOSE AND SCOPE This method is suitable for the identification and semi-quantitative determination of the following substances in hair dyes in cream or liquid form:

Substances Symbol Phenylenediamines o-Phenylenediamine (OPD) m-Phenylenediamine (MPD) p-Phenylenediamine (Annex V) (PPD)

(

) See Norm ISO 5725.

Substances Symbol Methylphenylenediamines 4-Methyl-1,2-phenylenediamine (toluene-3,4- diamine) (OTD) 4-Methyl-1,3-phenylenediamine (toluene-2,4- diamine) (MTD) 2-Methyl-1,4-phenylenediamine (toluene-2,5- diamine) (PTD) Diaminophenols 2,4-diaminophenol (DAP) Hydroquinone 1,4 Benzenediol (H) α-Naphthol (α-N) Pyrogallol 1,2,3-trihydroxybenzene (P) Resorcinol 1,3-dihydroxybenzene (R) 2. PRINCIPLE Oxidation colorants are extracted at pH 10 with96 % ethanol from dyes in cream or liquid form and identified by thin-layer chromatography, either one- or two-dimensional.

For semi-quantitative determination of these substances, the chromatogram of the samples is compared by means of four developing systems with those for reference substances produced at the same time and under as similar conditions as possible.

3.

REAGENTS All reagents should be of analytical purity.

3.1. Ethanol, anhydrous 3.2. Acetone 3.3. Ethanol, 96 % v/v 3.4. Ammonia solution, 25 % (d4 20 = 0·91) 3.5. L(+)-ascorbic acid 3.6. Chloroform 3.7. Cyclohexane 3.8. Nitrogen, technical grade 3.9. Toluene 3.10. Benzene 3.11. n-Butanol 3.12. Butan-2-ol 3.13. Hypophosphorous acid, 50 % v/v solution 3.14. Diazo reagent. Either: — 3-Nitro-1-benzenediazonium chlorobenzenesulphonate, (stabilized salt form) as in Red 2 JN — Francolor, — 2-Chloro-4-nitro-1-benzenediazonium naphthalenebenzoate (stabilized salt form) as in NNCD Reagent — reference No 74 150 FLUKA, or an equivalent.

3.15. Silver nitrate 3.16. p-Dimethylaminobenzaldehyde 3.17. 2,5-Dimethylphenol 3.18. Ferric chloride hexahydrate 3.19. Hydrochloric acid, 10 % m/v solution 3.20. Reference substances The reference substances are those shown in paragraph 1 ‘Purpose and scope’. In the case of amine compounds, the reference substance must be either the hydrochloride (mono or di) or the free base.

3.21. Reference solutions 0·5 % (m/v) A 0·5 % (m/v) solution of eachof the reference substances in Section 3.20 is prepared.

Weighout 50 mg ± 1 mg of he reference substance in a standard 10-ml flask.

Add 5 ml of 96 % ethanol (3.3) and 250 mg of ascorbic acid (3.5).

Make the solution alkaline by addition of the ammonia solution (3.4) to give an apparent pH of 10 (test withindicator paper).

Make up to 10 ml with96 % ethanol (3.3) and mix.

The solutions may be kept for a week in a cool place away from the light.

In certain cases, after the addition of the ascorbic acid and the ammonia, a precipitate may form. It should then be allowed to settle before proceeding.

3.22. Developing solvents 3.22.1. Acetone — chloroform — toluene (35: 25: 40 by vol) 3.22.2. Chloroform — cyclohexane — absolute ethanol — 25 % ammonia (80:

10: 10: 1 by vol) 3.22.3. Benzene — butan-2-ol — water (50: 25: 25 by vol). Shake well and use the upper phase after separating at room temperature (20 to 25 ºC).

3.22.4. n-Butanol — chloroform — reagent M (7: 70: 23 by vol). Separate carefully at room temperature (20 to 25 ºC) and use the lower phase.

Preparation of reagent M Ammonia solution, 25 % (v/v) 24 volumes Hypophosphorous acid, 50 % (3·13) 1 volume Water 75 volumes Note Developing solvents containing ammonia must be well shaken immediately before use.

3.23. Indicator sprays 3.23.1. Diazo reagent Make a 5 % (m/v) aqueous solution of the chosen reagent (3.14). This solution must be freshly prepared just before use.

3.23.2. Ehrlich's reagent Dissolve 2 g of p-diamethylaminobenzaldehyde (3.16) in 100 ml of hydrochloric acid 10 % (m/v) aqueous solution (3.19).

3.23.3. 2,5-dimethylphenol - ferric chloride hexahydrate Solution 1: Dissolve 1 g of dimethylphenol (3.17) in 100 ml of 96 % ethanol (3.3).

Solution 2: Dissolve 4 g of ferric chloride hexahydrate (3.18) in 100 ml of 96 % ethanol (3.3).

For development, these solutions are sprayed separately, first solution 1 then solution 2.

3.23.4. Ammoniacal silver nitrate 25 % ammonia (3.4) is added to 5 % (m/v) aq. solution of silver nitrate (3.15) until the precipitate just dissolves. This reagent must be prepared immediately before use.

Do not keep.

4.

APPARATUS 4.1. Usual laboratory equipment for thin-layer chromatography.

4.1.1. Plastics or glass cover to constructed that the chromatographic plate can be surrounded with0nitrogen during application of the0spots and drying.

This precaution is necessary because of the susceptibility to oxidation of certain colorants.

4.1.2. Micro-syringe, 10 µl, graduated in 0·2 µl divisions, witha square cut needle, or, better, a 50 µl repeating dispenser, mounted on a clamp stand in such a way that the plate can be kept under nitrogen.

4.1.3. Silica gel thin layer plates, ready to use, 0·25 mm thick, formed by 20 × 20 cm (Macherey and Nagel, Silica G-HR, which are on plastics support, or equivalent) 4.2. Centrifuge, 4 000 rev./min.

4.3. Centrifuge tubes, 10 ml withPTFE-lined screw caps, or equivalent 5. PROCEDURE 5.1. Treatment of test samples Discard the first 2 or 3 cm of cream extruded from the tube.

Put the following into a centrifuge tube (4.3) previously flushed out withnitrogen: 300 mg ascorbic acid with3 g cream or 3 g homogenized liquid.

Add 25 % ammonia drop-wise (3.4) until the pH is 10. Make up to 10 ml with96 % ethanol (3.3).

Homogenize under nitrogen (3.8), stopper and then centrifuge at 4 000 rev./min. for 10 minutes.

Use the supernatant liquid.

5.2. Chromatography 5.2.1. Spotting the plates Under an atmosphere of nitrogen (3.8), apply to a chromatography plate (4.1.3) 1 µl of eachof the above-described reference solutions at nine points situated about 1·5 cm apart along a line approximately 1·5 cm from the edge of the plate.

These reference solution spots are arranged as follows:

123456789 R P H PPD DAP PTD OPD OTD MPD MTD α-N In addition, apply at points 10 and 11 respectively 2 µl of the test solution samples obtained according to Section 5.1.

Keep the plate under nitrogen (3.8) until the moment when it is chromatographed.

5.2.2. Development Place the plate in a tank previously flushed out with nitrogen (3.8), saturated withone of the four solvents (3.22) and allow to develop at

room temperature (20 to 25 ºC) in the dark until the solvent front has moved about 15 cm from the baseline.

Remove the plate and dry under nitrogen (3.8) at room temperature.

5.2.3. Spraying Spray the plate immediately with one of the four solutions specified in 3.23.

5.2.4. Identification Compare the Rf value and the colour obtained from the sample with those of the reference substances chromatographed.

Table I gives as examples the Rf values and colours for eachsubstance depending on the solvent and indicator used.

Confirmation of doubtful identification may sometimes be achieved by a spiking method, adding the corresponding reference substance solution to the sample extract.

5.2.5. Semi-quantitative estimation Compare visually the intensity of the spots for each substance identified in 5.2.4 withan appropriate range of concentrations of the reference substances.

If the concentration of one or more of the substances found in the sample is excessive, dilute the sample extract and repeat the measurement.

TABLE I Rf values and colours obtained immediately after spraying Reference substance (3.20) Developing solvents Indicator sprays Rf values Resultant colours (3.22.1) (3.22.2) (3.22.3) (3.22.4) Diazo (3.23.1) Ehrlich (3.23.2) Dimethylphenol (3.23.3) AgNO (3.23.4) OPD 0·62 0·60 0·30 0·57 pale brown — — pale brown MPD 0·40 0·60 0·47 0·48 violet-brown (*) yellow pale brown pale brown PPD 0·20 0·50 0·30 0·48 brown bright red (*) violet grey OTD 0·60 0·60 0·53 0·60 brown (*) pale orange pale brown greyishbrown MTD 0·40 0·67 0·45 0·60 reddishbrown (*) yellow brown black PTD 0·33 0·65 0·37 0·70 brown orange violet (*) grey DAP 0·07 — 0 0·05 brown (*) orange violet brown H 0·50 0·35 0·80 0·20 — orange violet black (*) α-N 0·90 0·80 0·90 0·75 orange-brown — violet (*) black P 0·37 — 0·67 0·05 brown very pale violet very pale brown brown (*) R 0·50 0·37 0·80 0·17 orange (*) pale violet very pale brown pale brown Note1. OPD is only weakly shown up; the solvent (3.22.3) must be used to separate it clearly from the OTD.2. (*) Indicates the best colour development. ▼ B

6.

EXAMINATION BY TWO-DIMENSIONAL THIN-LAYER CHROMATOGRAPHY This two-dimensional chromatographic procedure requires the use of additional standards and reagents.

6.1. Additional reference solutions and substances 6.1.1. β -naphthol (β -N) 6.1.2. 2-aminophenol (OAP) 6.1.3. 3-aminophenol (MAP) 6.1.4. 4-aminophenol (PAP) 6.1.5. 2-nitro-1,4-phenylenediamine (2-NPPD) 6.1.6. 4-nitro-1,2-phenylenediamine (4-NOPD) Prepare a 0·5 % m/v solution of eachof the additional reference substances as described in 3.21.

6.2. Additional developing solvent 6.2.1. Ethyl acetate — cyclonexane — ammonia solution, 25 % (65: 30: 0·5 by vol) 6.3. Additional indication system Place a glass vessel in a developing tank for thin-layer chromatography, add about 2 g crystallized iodine and close the tank with an adequate lid.

6.4. Chromatography 6.4.1. Draw two lines, at shown in Figure 1, on the absorbent surface of a thin-layer plate (4.1.3).

6.4.2. Under a nitrogen atmosphere (4.1.1), apply 1 to 4 µl extract (5.1) at base point 1 (Figure 1) which is at 2 cm from the two sides. The quantity of extract depends on the intensity of the spots on the chromatograms 5.2.

6.4.3. Divide between points 2 and 3 (Figure 1) the oxidation colorants identified or assumed to be identified by 5.2 (distance between points 1·5 cm). Apply 2 µl of eachof the reference solutions — except DAP of which 6 µl must be applied. Conduct the operation under nitrogen (6.4.2).

6.4.4. Repeat the operation in 6.4.3 at base points 4 and 5 (Figure 1) and keep the plate under nitrogen until the moment it is chromatographed (distance between points 1·5 cm).

6.4.5. Flush out a chromatographic tank with nitrogen (3.8) and place in it a suitable quantity of developing solvent 3.22.2. Place the plate (6.4.4) in the tank and develop it in the first elution direction (Figure 1) in the dark.

Elute until the solvent front reaches the line marked on the plate (approximately 13 cm).

6.4.6. Remove the plate from the tank and place it in the chromatography tank previously flushed out with nitrogen to evaporate the elution solvent for at least 60 minutes.

6.4.7. Witha graduated test-tube, place a suitable quantity of elution solvent (6.2) in a tank flushed out with nitrogen (3.8), place the plate rotated through 90º in the tank (6.4.6) and chromatograph in the second direction (also in the dark) until the solvent front reaches the line drawn on the absorbent surface. Remove the plate from the tank and evaporate the elution solvent in air.

6.4.8. Place the plate for 10 minutes in the chromatography tank with iodine vapour (6.3) and interpret the two-way chromatogram using the Rf and colour values of the reference substances chromatographed at the same time (Table II gives a guide to the Rf values and colours).

Note To obtain maximum colouring of the spots leave the chromatogram exposed to the atmosphere for half an hour after developing.

This article is long: the rest is at the official publication.